PAC1934T-I/JQ, Strømstyrkemonitor, 16 ben, UQFN
- RS-varenummer:
- 179-3973
- Producentens varenummer:
- PAC1934T-I/JQ
- Brand:
- Microchip
Ikke tilgængelig
RS lagerfører ikke længere dette produkt
- RS-varenummer:
- 179-3973
- Producentens varenummer:
- PAC1934T-I/JQ
- Brand:
- Microchip
Egenskaber
Tekniske referencer
Lovgivning og oprindelsesland
Generel produktinformation
Find lignende produkter ved at vælge én eller flere attributter.
Vælg alle | Attribut | Værdi |
|---|---|---|
| Brand | Microchip | |
| Offset Voltage | ±0.1mV | |
| Kapslingstype | UQFN | |
| Benantal | 16 | |
| Monteringstype | Overflademontering | |
| Dimensioner | 4 x 4 x 0.5mm | |
| Indgangsspænding maks. | 5,5 V | |
| Indgangsspænding min. | 2,7 V | |
| Produktets højde | 0.5mm | |
| Produktets længde | 4mm | |
| Produktets bredde | 4mm | |
| Vælg alle | ||
|---|---|---|
Brand Microchip | ||
Offset Voltage ±0.1mV | ||
Kapslingstype UQFN | ||
Benantal 16 | ||
Monteringstype Overflademontering | ||
Dimensioner 4 x 4 x 0.5mm | ||
Indgangsspænding maks. 5,5 V | ||
Indgangsspænding min. 2,7 V | ||
Produktets højde 0.5mm | ||
Produktets længde 4mm | ||
Produktets bredde 4mm | ||
The PAC1932/3/4 are two, three and four-channel power and energy monitoring devices. A high-voltage multiplexer sequentially connects the inputs to a bus voltage monitor and current sense amplifier that feed high-resolution ADCs. Digital circuitry performs power calculations and energy accumulation. This enables energy monitoring with integration periods from 1 ms up to 36 hours or longer. Bus voltage, sense resistor voltage and accumulated proportional power are stored in registers for retrieval by the system master or Embedded Controller.
High-Side Current Monitor with 2, 3 or 4 Channels
100 mV full scale range for current sense voltage,16 bit resolution
Selectable bidirectional current sense
capability, -100 mV to +100 mV range, 16 bit
twos complement (signed) data format
External sense resistor sets full scale current range
Very low input current simplifies routing
Wide Bus Voltage Range for Voltage Monitor
0V to 32V input common-mode voltage
100 mV full scale range for current sense voltage,16 bit resolution
Selectable bidirectional current sense
capability, -100 mV to +100 mV range, 16 bit
twos complement (signed) data format
External sense resistor sets full scale current range
Very low input current simplifies routing
Wide Bus Voltage Range for Voltage Monitor
0V to 32V input common-mode voltage